| INVERTER SPECIFICATIONS | |
|---|---|
| Output Power (Continuous) | 1200 VA |
| Output Power (Peak) | 2000 VA |
| Output (Voltage, Frequency) | 230 VAC - 50 Hz |
| Output Current | 5.2 A |
| Output Waveform | True Sine Wave (<3% THD) |
| Peak efficiency | 90% |
| No-load battery draw | <1.5 A |
| 5V USB | 750 mA |
| DC Input Voltage (nominal) | 12.5 VDC |
| DC Input Operation Range | 10.5 - 15.5 VDC |
| DC Input Current | ~90 A |
| Input Undervoltage Warning / Shutdown | 11.3 / 10.5 V & 12.1 / 11.8 V |
| Input Undervoltage Recovery | 12 V & 12.6 V |
| Input Overvoltage Shutdown | 15.5 VDC |
| Output Power Warning / Shutdown | Warning / Error code |
| Output Short Circuit Protection | Error code |
| Temperature Warning / Shutdown | Warning / Error code |
| DETACHABLE DISPLAY | |
|---|---|
| Display Panel Port | RJ12 |
| Inverter Mode | Input V, Output Power |
| Charger Mode | Status, Battery Voltage |
| Warning and Fault Code | Yes |
| LED Indicator | Yes (Status, Display) |
| BATTERY CHARGER | |
|---|---|
| Charge Voltage Range | 13.5-14.4 V |
| Float Voltage Range | 13.4-13.8 V |
| Charger current (Maximum) | 40 A |
| Charger current setting (Manuals / Auto) | 5, 10, 20, 40 / Automatic |
| Charge Control | Bulk / Absorption / Float |
| Charging Battery Type | GEL, Flooded, AGM, Fixed |
| AC Input Voltage / Frequency | 230 VAC-50 Hz |
| AC Input Voltage Range | 180 - 260 VAC |
| Charger Efficiency | > 80% |
| Dead Battery Charging | 1VDC |
| Over Charge Protection | Yes, Error code |
| Over Temperature Protection | De-rated / Shutdown |
| AC TRANSFER SWITCH | |
|---|---|
| Transfer time | < 30 ms |
| Transfer Relay | 16 A |
| AC Input Source Setting | 8, 10, 16 A |
| AC Input Port | Heavy duty connector 16A max |
| AC Output Port 1 | Schuko, UK, Auz |
| AC Output Port 2 | Heavy duty connector 16A max |
| EGULATORY COMPLIANCE | |
|---|---|
| Standards | CE LVD |
| EMI/EMC | CE EMC |
Whisper Power WP Supreme Combi 12 V / 1200 VA - 40 A